AC-HPRO-4040 Acid-Resistant RO Membrane Element

The reverse osmosis series (AC-HPRO) is independently developed by Cooperate Technology for selective special separation.

Product Introduction

The reverse osmosis series (AC-HPRO) is independently developed by Cooperate Technology for selective special separation. Adopting proprietary membrane material manufacturing technology, this series enables long-term and stable operation under acidic conditions (pH 1-10).

Application Field
Hydrometallurgy / Non-ferrous Metals Industry
Waste acid recovery and Acid Washing Industry
Fine Chemicals & Pharmaceutical Intermediates
The electronics and Surface Treatment Industry
Separation of special chemical materials
Parameters

Model

Typical Stabilized

Salt Rejection 

(%)

Minimum

Salt Rejection 

(%)

Permeate Flow Rate GPD(m3/d)

Area ft² (m²)

AC-HPRO-4040

99.7

99.5%

1500 (5.7)

80 (7.5)

Test Condition

Test Solution

Tem.( ℃)

pH

Pressure psi (MPa)

Recovery(%)

32000mg/L NaCl

25

7.0

800 psi (5.5MPa)

8

 

1.Test Condition: 32000mg/L NaCl, 800 psi, 25℃, pH7

2.Flow rates for individual elements may vary but will be no more than ±15%

3.Active area guaranteed ±3%

Using Conditions

Maximum Operating Pressure

1300 psi(8.96MPa)

Maximum Operating Temperature

60 ℃

Maximum Feed Flow

16GPM  (3.6m3/h)

Maximum Feed Silt Density Index (SDI)

5.0

Application Environment (pH)

1-10

 Short-Term Cleaning (30 min.) pH Range

1-13

Maximum Pressure Drop Per Element

15psi (0.1Mpa)

Cautions

When the membrane element is first used, the water produced during the first hour should be discharged and not used.

When the membrane element is manufactured, the dry type membrane element has no protective liquid. Once the element gets wet, it should remain in a moist state.

The feed water pressure should be gradually increased within a time range of 30-60 seconds. Otherwise, it may cause irreversible damage to the membrane element.

At any time, back pressure on the water production side should be avoided.

The wet type membrane element is tested with water before leaving the factory, and is stored with a 1.5% sodium bisulfite solution (in winter, 10% propylene glycol antifreeze solution needs to be added). Then it is vacuum-packed.

When the system is shut down for a long time, to prevent the growth of microorganisms, it is recommended to immerse the membrane element in a 1.5% (by weight) sodium bisulfite protective liquid and replace the protective liquid regularly.

Users must strictly follow the operation limits and rules set in this manual. Otherwise, the company will not bear any consequences arising therefrom.

Users are strictly prohibited from using any chemical substances that are destructive to the membrane element during storage and operation. If such chemical substances are used, the company will not bear any consequences arising therefrom.