BWRO-8040-400FR Fouling-Resistant Brackish Water Reverse Osmosis Membrane Element

Highly effective cleaning performance, robustness, and durability due to its wide cleaning pH range (1~13).

Product Introduction

Highly effective cleaning performance, robustness, and durability due to its wide cleaning pH range (1~13). A 34-mil feed spacer to lessen the impact of fouling on pressure drop across a vessel and enhance cleaning effectiveness. Automated, precision fabrication with membrane leaf efficiencies optimized to reduce the overall effect of fouling

Application Field
Industrial Wastewater Reuse
Demineralization for industrial applications, such as: Power Generation, Steel & Metal, Chemical & Petrochemical.
Product Features
Model:
BWRO-8040-400FR
Typical Stabilized Salt Rejection (%):
99.7
Minimum Salt Rejection (%):
99.4
Permeate Flow Rate GPD(m³/d):
11000(41.6)
Area ft² (m²):
400(37.2)
Test Condition

Test Solution

Tem.( ℃)

pH

Pressure psi (MPa)

Recovery(%)

2000mg/L NaCl

25

8.0

225 psi (1.55MPa)

15

 

1.Test Condition: 2000mg/L NaCl, 225 psi, 25℃, pH7
2.Flow rates for individual elements may vary but will be no more than ±15%
3.Active area guaranteed ±3%

Using Conditions
Maximum Operating Pressure 600 psi (4.14 MPa)
Maximum Operating Temperature  45 ℃
Maximum Feed Flow 84 GPM (19 m³/h)
Maximum Feed Silt Density Index (SDI)  5.0
Continuous Operation pH Range  2–11
Short-Term Cleaning (30 min.) pH Range  1–13
Maximum Pressure Drop per Element 15 psi (0.1 MPa)
Cautions

When the membrane element is first used, the water produced during the first hour should be discharged and not used.

When the membrane element is manufactured, the dry type membrane element has no protective liquid. Once the element gets wet, it should remain in a moist state.

The feed water pressure should be gradually increased within a time range of 30-60 seconds. Otherwise, it may cause irreversible damage to the membrane element.

At any time, back pressure on the water production side should be avoided.

The wet type membrane element is tested with water before leaving the factory, and is stored with a 1.5% sodium bisulfite solution (in winter, 10% propylene glycol antifreeze solution needs to be added). Then it is vacuum-packed.

When the system is shut down for a long time, to prevent the growth of microorganisms, it is recommended to immerse the membrane element in a 1.5% (by weight) sodium bisulfite protective liquid and replace the protective liquid regularly.

Users must strictly follow the operation limits and rules set in this manual. Otherwise, the company will not bear any consequences arising therefrom.

Users are strictly prohibited from using any chemical substances that are destructive to the membrane element during storage and operation. If such chemical substances are used, the company will not bear any consequences arising therefrom.

Dimensions and Packaging

796ae30b-09c4-4e76-a4b8-52cb4da138b3_看图王.jpg

Product Feedback

Please provide the following valid information, and we will contact you as soon as possible

boruike15@gmail.com
+86 15556910898
For More Cooperate Information