Anhui Cooperate Environmental Technology Co., Ltd.
|
Model |
Typical Stabilized Salt Rejection (%) |
Minimum Salt Rejection (%) |
Boron Rejection (%) |
Permeate Flow Rate GPD(m3/d) |
Area ft2 (m2) |
|
SWRO-8040-400HF |
99.80 |
99.60 |
91.00 |
9000 (34.1) |
400 (37.2) |
|
Test Solution |
Tem.( ℃) |
pH |
Pressure psi (MPa) |
Recovery(%) |
|
32000mg/L NaCl |
25 |
8.0 |
800 psi (5.52MPa) |
8 |
1.Test Condition: 32,000ppm NaCl, 5ppm B, 800psi (55.2 bar), 25℃ (77℉), pH=8
2.Flow rates for individual elements may vary but will be no more than ±15%
3.Active area guaranteed ±3%
|
Maximum Operating Pressure |
1200 psi (8.30MPa) |
|
Maximum Operating Temperature |
45 ℃ |
|
Maximum Feed Flow |
75GPM (17m3/h) |
|
Maximum Feed Silt Density Index (SDI) |
5.0 |
|
Continuous Operation pH Range |
2-11 |
|
Short-Term Cleaning (30 min.) pH Range |
1-13 |
|
Maximum Pressure Drop Per Element |
15psi (0.1Mpa) |
● When the membrane element is first used, the water produced during the first hour should be discharged and not used.
● When the membrane element is manufactured, the dry type membrane element has no protective liquid. Once the element gets wet, it should remain in a moist state.
● The feed water pressure should be gradually increased within a time range of 30-60 seconds. Otherwise, it may cause irreversible damage to the membrane element.
● At any time, back pressure on the water production side should be avoided.
● The wet type membrane element is tested with water before leaving the factory, and is stored with a 1.5% sodium bisulfite solution (in winter, 10% propylene glycol antifreeze solution needs to be added). Then it is vacuum-packed.
● When the system is shut down for a long time, to prevent the growth of microorganisms, it is recommended to immerse the membrane element in a 1.5% (by weight) sodium bisulfite protective liquid and replace the protective liquid regularly.
● Users must strictly follow the operation limits and rules set in this manual. Otherwise, the company will not bear any consequences arising therefrom.
● Users are strictly prohibited from using any chemical substances that are destructive to the membrane element during storage and operation. If such chemical substances are used, the company will not bear any consequences arising therefrom.