PTFE-TMCS-2020 Membrane Contactor

Cooperate has developed a membrane contactor using PTFE hollow fiber membrane for efficient and cost-effective ammonia nitrogen removal.

Product Introduction

Cooperate has developed a membrane contactor using PTFE hollow fiber membrane for efficient and cost-effective ammonia nitrogen removal.4

Application Field
Removal of ammonia nitrogen from ternary precursor and semiconductor wastewater.
Chemical, pharmaceutical, pesticide, metallurgy, municipal sewage, and landfill leachate.
Extraction of bromine from seawater, concentrated seawater, underground brine, chemical feed liquid, etc.
Product Features
1:
Efficient removal of ammonia nitrogen-
2:
Operates at near-normal pressure with low energy consumption and minimal operating costs
3:
Providing corrosion resistance, high resistance to strong acids and alkalis, high-temperature resistance, strong hydrophobicity, and a long service life
4:
Possesses uniform pores and a narrow pore size distribution to prevent concentration polarization and scaling
5:
Strong resistance to fluid impact, eliminating the risk of broken fibers
Material
Components Materia
Shell UPVC 
Membrane PTFE 
Sealing ring EPMD
Potting Epoxy resin 
Specification
Membrane area  1.7m² 
Membrane pore size  0.1μm​ 

Design water flow 

10-30L/h 
Design water inlet pressure  0.02-0.05MPa 
Design water inlet temperature  35-45 ℃ 
Design inlet water pH  >11
Design acid inlet pressure  0.02-0.05MPa 
Design acid inlet temperature  5-45℃ 
Design acid inlet pH  1-2 
Experimental Data
f4f91916-01fa-481b-bb8b-69d34fc5c0e6.png 819fe0d7-98ac-40cd-b8af-eace69f2184a.png
Note: The ammonia nitrogen content of the raw water is 2076ppm,  pH=12.18, the raw water temperature is raised to 45℃, and the pH value of the sulfuric acid absorption liquid is maintained below 1. The above test data is the removed racial average level curve of ammonia nitrogen wastewater passing through the deammoniation membrane shell, and the individual deviation of the membrane contactor from the average level is within ±3%. Note: The ammonia nitrogen content of the raw water is 2076ppm,  pH=12.18, the raw water temperature is raised to 45℃, and the pH value of the sulfuric acid absorption liquid is maintained below 1. The above test data is the removed racial average level curve of ammonia nitrogen wastewater passing through the deammoniation membrane lumen side, and the individual deviation of the membrane contactor from the average level is within ±3%.