PTFE-MBC-004D membrane contactor

Cooperate's anti-static MBC-004D membrane contactor utilizes a unique PTFE hollow fiber as a dissolved gas medium, ensuring quick and controllable CO2 dissolving.

Product Introduction

Cooperate's anti-static MBC-004D membrane contactor utilizes a unique PTFE hollow fiber as a dissolved gas medium, ensuring quick and controllable CO2 dissolving. It effectively maintains system outlet stability, improving gas utilization efficiency and reducing gas consumption.

Application Field
Microcircuit chip cutting and cleaning
Photomask cutting and cleaning
Wafer cutting and cleaning
Semiconductor silicon wafer cutting and cleaning
Solar cell cutting and cleaning
Controlled ultrapure water resistors for special industries
Product Features
1:
Ultra-clean, no secondary pollution
2:
High gas dissolution efficiency
3:
The resistivity of produced water is stable
4:
Longer component life
5:
High gas utilization rate, saving gas consumption
6:
Cooperate's unique PTFE hollow fibertechnology
7:
Small size, small footprint, large flow rate of membrane contactor
Material
Components Materia
Shell End cap PP , Cylinder PPO
Membrane PTFE
Sealing ring FFKM
Potting Eletronic grade epoxy resin
Specification
Flow rate range 3-400L/h
Membrane area 2.0m²
Interface Liquid inlet and outlet RC 3/8
Interface Gas phase interface RC 1/4
Maximum operating temperature 55 ℃ /131 ℉
Maximum operating pressure 0.3MPa@55°C
Maximum vacuum pressure -98KPa
Save method Dry storage
Experimental data
Source water 
resistance rate
( MΩ.cm )
Set resistance value 
ratio
( MΩ.cm )
Source water flow
( L/min )
CO2 pressure value 
( Kpa )
Measured resistivity
( MΩ.cm )

13.75

0.2

75

100

0.21-0.22

13.75

0.5

75

20

0.49-0.52

13.75

2

75

5

1.99-2.10

13.75

0.6

46

10

0.52-0.56

13.75

0.2

16

5

0.21

Note:The test temperature is 25℃ , and the test liquid is 13.75MΩ·cm ultrapure water. The above carbon charging efficiency data is the average level curve of this type of membrane contactor, and the deviation between the individual membrane contactor and the average 
level is within ±3% .

Product Feedback

Please provide the following valid information, and we will contact you as soon as possible

boruike15@gmail.com