Anhui Cooperate Environmental Technology Co., Ltd.
Outside-in ultrafiltration is widely used in condensate water, circulating water, wastewater treatment and other applications.
Outside-in ultrafiltration is widely used in condensate water, circulating water, wastewater treatment and other applications. It is often employed as pretreatment for NF and RO processes, such as in reclaimed water reuse, industrial wastewater discharge, seawater desalination and other fields.
| Fiber Manufacturing Process | TIPS (Thermal Method) |
| Fiber Material | PVDF |
| Operation Mode | O-I (Outside-in) |
| Module Diameter | 225 mm |
| Effective Membrane Area | 77 m² |
| Nominal Pore Size | 0.08 μm |
| Module Volume | 39 L |
| Net Weight of Module | 66 kg |
| Recommended Flux | 40–120 LMH |
| Recommended Flow Rate | 3.2-9.6m²/h |
| Permeate Turbidity | ≤0.1 NTU |
| Permeate SDI₁₅ | ≤2.5 NA |
| Max. Tolerable TSS | 100 ppm |
| Max. Inlet Turbidity | 300 NTU |
| Continuous Operating pH Range | 2 – 11 |
| Operating Temperature Range | 1 – 45 ℃ |
| Max. Inlet Pressure | 6.0 Bar |
| Max. Backwash Pressure | 2.5 Bar |
| Max. Trans-Membrane Pressure (TMP) | 3.0 Bar |
| Max. Aeration Pressure | 2.5 Bar |
| Recommended Air Scour Flow Rate | 5 – 12 Nm³/h |
The above are general limits. For specific projects, conservative operating parameters ensure better performance and longer service life.
Maximum sodium hypochlorite resistance concentration: 10000 ppm, recommended cleaning temperature: 20-40 ℃, chemical cleaning pH range: 1-14 NA.
● During the first hour of initial use of the membrane element, the produced water shall be drained and not used.
● Dry membrane elements are shipped without preservation solution. Once wetted, the elements must be kept moist at all times.
● Feed water pressure should be increased gradually over a period of 30–60 seconds; otherwise, irreversible damage to the membrane element may occur.
● Back pressure on the permeate side must be avoided at all times.
● Wet membrane elements are tested with water before shipment, preserved in a 1.5% sodium bisulfite solution (10% propylene glycol antifreeze added in winter), and then vacuum-packed.
● For long-term system shutdowns, to prevent microbial growth, it is recommended that the membrane elements be immersed in a 1.5% (w/w) food-grade sodium bisulfite preservation solution, which should be replaced regularly.
● Users must strictly follow the operating limits and guidelines specified in this manual; otherwise, the company shall not be liable for any consequences arising therefrom.
● Users are strictly prohibited from using any chemicals that may damage the membrane elements during storage and operation. The company shall not be liable for any consequences resulting from the use of such chemicals in violation of this requirement.

Note: Product performance may vary under different conditions. The information in this document is for reference only and shall not be used as a basis for performance guarantee in actual applications. Users are responsible for determining whether the products and information in this document are suitable for the application environment and ensuring that the use of the products complies with applicable laws and regulations. Kenano Membrane Technology shall not assume any obligation or liability for the information in this document. All consequences arising from the user's failure to use and maintain the products in accordance with the conditions provided in this brochure shall have nothing to do with the company. Due to technological progress and product upgrading, product information may change at any time without prior notice. Please pay attention to the latest product information.